Controlador de Velocidade de Motor Pwm dc 1055v Visor Digital Lcd com Função de Limite de Temporização Controle Remoto 12v 24v 36v 48v
R$ 147,44
DÚVIDAS?
Envie um email para:
Controlador do Motor
Opção de Compra e tempo de entrega
Ficha técnica do produto
Características | Especificações |
---|---|
Número do Modelo | PWM DC Motor Speed Controller |
Tipo de Motor | Motor CC |
Nome da Marca | Aideepen |
Origem | CN (origem) |
Features
Intelligent LCD screen with backlight, able to display working time, speed percentage, current mode, forward rotation, reverse state, etc.
Equipped with wireless remote control
Multiple limit modes are available
Slow start and slow stop time can be set
The upper limit and lower limit of the speed can be set
The total working time can be set.
Support two-speed control of forward rotation speed and reverse rotation speed separately
Two modes of manual and automatic are optional. Automatic mode is fully automatic forward and reverse within the set time
Touch switch to switch forward and reverse, jog acceleration and deceleration, solve the problem of traditional potentiometers
Product parameter
Input voltage: DC10-55V (the specific voltage is equal to the rated voltage of the motor)
Output voltage: linear under load
Momentary current: 50A s
Continuous current: within 30A
Forward and reverse: support for the support of the
Wireless remote control: Yes
Timing timing: Yes
Limit function: Yes
Slow start and stop: Can be set
Speed digital display: 0-100 percentage meter
Speed regulation type: flow regulation
Speed adjustment method: jog +-
Speed adjustment range: 0——100%
Control frequency: 15KHZ
Wiring type: Fence type terminal block
Support motor: brushed motor
Module size: length * height * depth 105mm*70mm*95mm
Product net weight: 275 grams
Panel opening: length*width 98mm*63mm
Installation method: Embedded
Long press theMENUbutton to turn off the backlight
If you need reverse start, press FWD/REV reverse start
Note: The input must be divided into positive and negative. The input voltage must be equal to the rated voltage of the motor (within 10-55V)
For example, the rated voltage of the motor is 12V and the voltage of the governor is 12V. The rated voltage of the motor is 36V and the voltage of the governor is 36V.
Input 220V will burn out
The wiring of the two-wire three-wire limit switch is shown in the figure below
Support normally open mechanical switch, NPN type photoelectric switch, metal proximity switch, Hall magnetic control switch
0-1-2-3-4-5-6-7-8-9-E functions are set as follows
Manual automatic mode selectionfunction 0: 1 is manual mode 2 is automatic mode The default is 1 manual mode.
Slow start time settingFunction 1: 000-100 The slow start to 100% speed time is adjustable between 0-10 seconds. The default is 1 second.
Slow stop time settingFunction 2: 000-100 The slow stop time is adjustable between 0-10 seconds. The default is 1 second.
Speed lower limit settingfunction 3: 000-080 The minimum speed is adjustable between 0-80% and less than the maximum speed setting value. The default is 0.
Speed limit settingfunction 4: 000-100 The maximum speed is adjustable between 0-100% and is greater than the minimum speed setting value. The default is 100%.
The acceleration and deceleration value settingfunction 5: 001 002 005 010 015 020 025 The speed changes 1%, 2%, 5%, 10%, 15%, 20%, 25% every time you press the plus and minus key.
Motor total running time settingFunction 6: 0 seconds minimum -999 hours 59 minutes 59 seconds maximum The default is 0 hours 0 minutes 0 seconds No timing function.
The following function 7.8.9. is the time setting in the fully automatic mode
Forward rotation time settingFunction 7: 0 seconds minimum -999 hours 59 minutes 59 seconds maximum The default is 10 seconds
Stop time settingFunction 8: 0 seconds minimum -999 hours 59 minutes 59 seconds maximum The default is 10 seconds
Reverse time settingfunction 9: 0 seconds minimum -999 hours 59 minutes 59 seconds maximum The default is 10 seconds
Limit mode selectionFunction E: E1 Infinite position Default infinite position
E2 Press to start the motor forward rotation, forward rotation to the positive limit, and the motor stops. Press the forward and reverse keys to reverse the start
E3 According to the start of the motor forward rotation, forward rotation to the positive limit motor reverse rotation, reverse rotation to the negative limit motor stop
E4 According to the starting motor forward rotation, forward rotation to positive limit, the motor reverse rotation and work cycle
Manual and automatic mode selection Press theMENUbutton 1 to display 0 Enter manual and automatic mode selection 1 is manual mode 2 is automatic mode Press the plus and minus keys to switch Press RUN/STOP to save and exit
Start-up time setting Press the MENU key 2 to enter the function 1 setting key surface Press the plus and minus keys to set the time Press RUN/STOP to save and exit (10 is 1 second, 100 is 10 seconds)
Slow stop time setting Press theMENUkey 3 times to enter the function 2 setting key surface Press the plus and minus keys to set the time Press RUN/STOP to save and exit (10 is 1 second, 100 is 10 seconds
Speed lower limit setting Press theMENUkey 4 times to enter the function 3 key surface Press the plus and minus keys to set Press RUN/STOP to save and exit
Speed limit setting Press theMENUkey 5 times to enter the function 4 key surface Press the plus and minus keys to set the size value Press RUN/STOP to save and exit
Set acceleration and deceleration values Press theMENUkey 6 times to enter the function 5 key surface Press the plus and minus keys to switch Press RUN/STOP to save and exit
Motor running time setting
Press theMENUkey 7 times to enter the function 6 key surface The default is the maximum time 0 hour 0 minute 0 second FWD/REV key switch hour minute second
Press plus or minus to adjust the hour, minute, second size Press RUN/STOP to save and exit
Function 7 Forward rotation time setting in fully automatic mode
Press theMENUkey 8 times to enter the function 7 key surface The default is the maximum time 0 hour 0 minute 10 seconds FWD/REV key switch hour minutes seconds
Press plus or minus to adjust the hour, minute, second size Press RUN/STOP to save and exit
Function 8 Stop rotation time setting in fully automatic mode
Press theMENUbutton 9 times to enter the function 8 key surface The default is the maximum time 0 hour 0 minute 0 second FWD/REV key switch hour minute second
Press plus or minus to adjust the hour, minute, second size Press RUN/STOP to save and exit
Function 9 Reverse time setting in fully automatic mode
Press theMENUkey 10 times to enter the function 9 key surface The default is the maximum time 0 hour 0 minute 10 seconds FWD/REV key switch hour minutes seconds
Press plus or minus to adjust the hour, minute, second size Press RUN/STOP to save and exit
Function E limit mode selection E1 E2 E3 E4
Press theMENUkey 11 times to enter the function E key surface, the default is E1 unlimited digits Press plus and minus switch E1 E2 E3 E4 Press RUN/STOP to save and exit
E2 function: Press to start the motor to rotate forward, to rotate to the positive limit, and the motor to stop. Press the positive and negative keys to reverse and start
E3 function: according to the starting motor forward rotation, forward rotation to positive limit motor reverse rotation, reverse rotation to reverse limit motor stop
E4 function: according to the starting motor forward rotation, forward rotation to the positive limit motor reverse rotation cycle work
Panel opening length 98 mm wide 63mm
1. Controlador de Velocidade de Motor Pwm dc – tipo de Óculos : Óculos de Leitura
Avaliações de Usuários
Seja o primeiro a avaliar “Controlador de Velocidade de Motor Pwm dc 1055v Visor Digital Lcd com Função de Limite de Temporização Controle Remoto 12v 24v 36v 48v”
R$ 147,44
Não existe nenhuma avaliação ainda.