Controlador de Nível de Água Automático Controlador de Bomba Cisterna Interruptor Líquido Automático Trilho Din Df-96d Df96dk 220v
Original price was: R$ 98,13.R$ 78,53Current price is: R$ 78,53.
DÚVIDAS?
Envie um email para:
Interruptores e Acessórios
Vídeo de Demonstração do Produto
Opção de Compra e tempo de entrega
Ficha técnica do produto
Características | Especificações |
---|---|
Material | Plástico |
Características | Water |
Número do Modelo | Df-96d AND Df-96dk |
Interruptor | Interruptor do Sensor |
Garantia | |
Certificado | CE |
Nome da Marca | Dianqi |
Origem | CN (origem) |
Tipo de Item | Interruptores |
Model1 | Df-96d(no Onoff Switch) NO 3wires |
Model2 | Df-96d(no Onoff Switch)with 3 Wires |
Model3 | Df-96dk(with Onoff Switch)no 3wires |
Model4 | Df-96dk(with Onoff Switch) With 3 Wires |
Model5 | Df-96dk(russian With Onoff Switch)no 3wires |
Model6 | Df-96dk(russian With Onoff Switch)with 3 Wires |
Note!! | Please Choose THE Correct Option!different Price ! |
1. Renovação da Casa
A(red)—Upper water level control point. When water level gets to A point,
the probe touch water and controller can stop the pump by auto.
B(blue)—Lower water level control point. When water level gets off B point,
the probe out of reach water and controller can start the pump by auto.
C(black)—Should be placed in bottom of pool as the common line.
D(green) and E(yellow)are connected with C (black).
Single-control DOWN pool(drain water)installation instructions shown in figure 2.
2. Controlador de Nível de Água Automático Controlador
E—Upper water level control point. When water level gets to E point,
the probe touch water and controller can start the pump by auto.
D—Lower water level control point. As liquid level gets off D point,
the probe out of reach water and controller can stop the pump by auto.
C—Should be placed in bottom of pool as the common line.
A&B—disconnected
Lack of water protection installation instructions shown in figure 3.
3. Cheap Interr.
C&D—Lower water level control points. When water level gets off this point,
C or D probe out of reach water and controller can stop the pump by auto.
E&C—short-connected;
A&B—disconnected
Joint control UP and DOWN pool installation instructions shown in figure 4.
4. de Bomba Cisterna Interruptor Líquido Automático Trilho Din Df-96d Df96dk 220v
A—Upper water level control point in UP pool. When water level gets to A point,the probe touch water and controller can stop the pump by auto.
B—Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
C—Should be placed in bottom of UP and DOWN pools as the common line.
D—Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.
E—Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Used to solve problem:
1. On power but no work:
a. Check the red indicator is on or not. If not, make the connection is good enough;
2. When water level is above or below probes but the pump does not start or stop by auto, Please check it like the following.
a. Whether the probe is placed too high or low so that water level can reach or out of reach it;
b. The connection of upper &lower line or probe is dislocation by error or short connected;
c. To check the probe whether it is rust or not or the connection is good enough.
d. C- Check the common line whether it is placed in the lowermost bottom of pool.
Specification :
5. High Quality Renovação da Casa
6. Renovação da Casa
7. Controlador de Nível de Água Automático Controlador
Avaliações de Usuários
Seja o primeiro a avaliar “Controlador de Nível de Água Automático Controlador de Bomba Cisterna Interruptor Líquido Automático Trilho Din Df-96d Df96dk 220v”
Original price was: R$ 98,13.R$ 78,53Current price is: R$ 78,53.